Kugwiritsa Ntchito Zowona Zachilengedwe Kuwongolera Data Center Energy Consumption

Malo opangira data ndi ogwiritsa ntchito magetsi ambiri.Ndi kukula kwamphamvu kwa digito, ma data akulu, malonda a e-commerce, ndi kuchuluka kwa intaneti, malo opangira ma data akhala amodzi mwa ogwiritsa ntchito mphamvu padziko lonse lapansi omwe akukula mwachangu.Malinga ndi kafukufuku waposachedwa ndi ResearchandMarkets, kugwiritsa ntchito mphamvu m'malo opangira ma data kukukwera mwachangu chifukwa chakukula mwachangu padziko lonse lapansi komanso kufunikira kwa ntchito zamagetsi zamagetsi.Pofika 2020, msika wa data center power services ukuyembekezeka kukula pa Compound Annual Growth Rate (CAGR) ya 11.8%, kufika $20.44 biliyoni.

Malo opangira ma data amawononga 3% ya magetsi padziko lonse lapansi ndipo amawerengera 2% ya mpweya wowonjezera kutentha.Kutumiza mphamvu, kugwiritsa ntchito, ndi kuwongolera kutentha ndizovuta kwambiri m'malo a data center.Ngakhale kusinthasintha kwakung'ono kwa kutentha kwa chilengedwe kungakhudze kwambiri kugwiritsa ntchito mphamvu.Chifukwa chake, kuyang'anira zachilengedwe ndi mapu a nthawi yeniyeni komanso zowona za data center zitha kuthandiza oyang'anira ma data ndikuwachenjeza za zomwe zingachitike mongamadzi akuchucha, kusuta, ndi kutsegula zitseko za kabati.Izimasensakuthandiza kupewa overcooling, kutentha kwambiri, electrostatic discharge, dzimbiri, ndi mabwalo aafupi, etc. YOSUNsmart PDUadapangidwa mwapadera kuti azigwira ntchito ndi masensa awa.Nazi njira zisanu zofunika zomwe masensa achilengedwe angathandizire oyang'anira ma data:

31

1.Zomverera za KutenthaKupulumutsa Mtengo Wozizira: Zipangizo zapakati pa data ziyenera kusungidwa mkati mwa kutentha kwapadera kuti zigwire bwino ntchito ndikuletsa kuwonongeka kwa hardware.Amafuna mpweya wozizira ndi mpweya wabwino kuti ukhalebe wozizira.Oyang'anira malo a data atha kugwiritsa ntchito data ya kutentha kukhathamiritsa makina ozizirira, kuzindikira malo omwe ali ndi malo ambiri, ndikutsitsa chipangizo chimodzi kapena zingapo ngati pakufunika.Masensa a kutentha pazipinda zopangira rack amapereka mawonedwe olondola komanso a nthawi yeniyeni ya kutentha kwa data poyerekeza ndi kuwerenga kwa mayunitsi a Computer Room Air Conditioning (CRAC).Masensa ena a kutentha ndi chinyezi amapangidwa motsatira malangizo a American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) kuti apeze zowerengera zolondola komanso zomveka kuchokera pamwamba, pakati, ndi pansi pa rack.

32

 

2.Kuwonjezeka kwa Uptime ndi Airflow Monitoring: Oyang'anira malo opangira data atha kupulumutsa ndalama zambiri pochepetsa kuyenda kwa mpweya kukhala voliyumu yofunikira yokha.Masensa a Airflow amathandiza oyang'anira malo a data kuti aziyang'anira kuzizira kwa mpweya ndi kubwerera kwa mpweya wotentha kuti atsimikizire kuti njira yozizira ikugwira ntchito bwino.Amawonetsetsanso kuti mpweya wotuluka uli pamlingo woyenera kuti choyikapo chonsecho chilandire mpweya wabwino wolowera.Ma sensor osiyanasiyana a air pressure amathandizira oyang'anira malo a data kuonetsetsa kuti mpweya ukuyenda mokwanira.Masensa awa amatha kuzindikira kusiyana kwa kuthamanga kwa mpweya komwe kungayambitse kutulutsa kotentha kwa kanjira / kozizira ndikugwiritsidwa ntchito kuwongolera magawo a CRAC.Masensa apansi apansi apansi amapereka ndemanga kwa Computer Room Air Handler (CRAH), CRAC, kapena Building Management Systems (BMS) kuti asinthe liwiro la mafani kuti agwirizane ndi kupanikizika kwapansi pansi.

33

 

3. Ma Racks Otetezedwa a Cabinet okhala ndi Masensa Otseka Olumikizana:Masensa otseka olumikizana amatsimikizira chitetezo cha ma racks a cabinet.Atha kugwiritsidwa ntchito kuyambitsa zochitika, monga kujambula zithunzi ndi makamera a netiweki pomwe zitseko za kabati zimawoneka ngati zotseguka.Zowuma zotsekera zolumikizira zimatha kugwiritsidwa ntchito pazida zachitatu, monga zowunikira utsi, kutumiza ma alarm amoto kwa oyang'anira malo a data ndikuwona khomo lamagetsi lotseguka / lotseka.Izi zimathandiza kuti zida zotetezedwa zisinthe.

https://www.yosunpdu.com/accessory

4. Kulandira Zidziwitso Zachilengedwe:Oyang'anira ma data atha kukhazikitsa malire ndi zidziwitso kuti aziyang'anira malo omwe ali pamalopo, akutali, kapena osayendetsedwa ndi anthu kuti atsimikizire kuti zida zikugwira ntchito motetezeka.Zowunikira zachilengedwe monga chinyezi ndi zowunikira madzi zimathandizira kuteteza zida zamtengo wapatali ndikuchotsa nthawi yotsika mtengo yobwera chifukwa cha kulephera kwa zida za IT.Masensa a chinyezi amathandizira kukhalabe ndi chinyezi choyenera, kupewa zovuta za electrostatic discharge (ESD) pa chinyezi chochepa komanso zovuta za condensation pa chinyezi chambiri.Zowunikira madzi zimazindikira ngati madzi akuchokera kunja kapena kutayikira kwa mapaipi mkati mwa zotchingira madzi.

https://www.yosunpdu.com/water-sensor-product

5. Kupanga ndi Kusintha Deta Center Infrastructure:Zowunikira zachilengedwe zimakupatsani mwayi wozindikira zomwe zikuchitika, kulandira zidziwitso, kukulitsa kupezeka kwa data pakati, ndikupulumutsa mphamvu.Amathandizira kuzindikira ndikubwezeretsanso kuchuluka kwa data komwe sikunagwiritsidwe ntchito bwino, kuchedwetsa kuyika ndalama pazida ndi zida.Mwa kuphatikiza masensa a chilengedwe ndi mayankho a Data Center Infrastructure Management (DCIM), oyang'anira malo a data amatha kuyang'anira kutentha munthawi yeniyeni ndikuwerengera ndalama zomwe zingasungidwe.Kukonza malo osungiramo data kumathandizira kuchepetsa ndalama zogwirira ntchito ndikuwongolera Kugwiritsa Ntchito Mphamvu Mwachangu (PUE).

36


Nthawi yotumiza: Aug-05-2023